Power Options
In all power schemes a fuse of 4 A slow is required in the power supply lines.
The connection to the power supply should be done by a qualified technician
only.
Use a Class 2 power supply only.
The power supply should be conform to DIN EN 60 742 (VDE 0551)
On the bottom rear end a connection to functional earth is recommended. This
connection is recommended by a 4 mm² cable with a 6.3 female spade termi
nal, the IE-SW14 to 24-M Line has the male spade terminal.
The IE-SW-14 to 24-M Switch does NOT charge
the battery, so separate provisions charching are
required.