Weidmuller IE-MC-VL Series Guia de Instalação Página 11

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 14
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 10
Dip Switch Setting
IE-MC-VL Series DIP switch
123
ON DIP
Dip Switch 1 (Default: Off )
ON: Enables the PORT Alarm. If the port’s link fails,
the relay will form an open circuit and the fault
LED will light up.
Off: Disables the corresponding PORT Alarm. The
relay will form a closed circuit and the Fault
LED will never light up.
Dip Switch 2 (Default: ON )
ON: Enables full duplex for 100BaseFX
Off: Disables full duplex for 100BaseFX
Dip Switch 3
Reserved for future use
To activate the updated DIP switch settings, power off and then
power on the Media Converter.
LED Indicators
The front panel of the Media Converter contains several LED
indicators. The function of each LED is described in the table below.
LED Color State Description
On
Power is being supplied to
power input PWR1
PWR1 AMBER
Off
Power is not being supplied
to power input PWR1
On
Power is being supplied to
power input PWR2
PWR2 AMBER
Off
Power is not being supplied
to power input PWR2
On
When the corresponding
PORT alarm is enabled,
and the port’s link is
inactive.
FAULT RED
Off
When the corresponding
PORT alarm is enabled and
the port’s link is active, or
when the corresponding
PORT alarm is disabled.
On
TP port’s 10 Mbps link is
active
Blinking
Data is being transmitted at
10 Mbps
10M GREEN
Off
TP Port’s 10 Mbps link is
inactive
100M GREEN
On
TP port’s 100 Mbps link is
active
- 11 -