• Operation
General
The UHZ/AR is an auxiliary powered, signal converter for frequency
based signals. It has two alarm channels and a digital display built in.
The maximum input frequency of 10 kHz (with overrange to 16 kHz).
Input type selection
To set up the unit for a particular input waveform you set the input
trigger/reset voltages using the input type setting. The trigger/reset
voltages are shown in a table on page 23. Use contact closure type for
volt-free contacts as this includes debouncing (maximum frequency
10 Hz). All other input types shown use the high level dc setting. If you
need more help with this selection, please contact technical support.
UHZ/AR block diagram.
Signal from
frequency source
Analogue Output
Alarm 1
Alarm 2
Power Supply
Sensor supply (Out)