Weidmuller DPATCX - Universal glavanically isolated signal co Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Hardware Weidmuller DPATCX - Universal glavanically isolated signal co. Weidmuller DPATCX - Universal glavanically isolated signal converter Benutzerhandbuch Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 28
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
de
en
DPA/TCX 61001041/00/04.08
Bedienungsanleitung
Zweikanaliges
Grenzwertüberwachungsmodul 3
Operating instructions
Two-channel
threshold monitoring module 16
Vista de página 0
1 2 3 4 5 6 ... 27 28

Resumo do Conteúdo

Página 1 - Operating instructions

deenDPA/TCX 61001041/00/04.08BedienungsanleitungZweikanaliges Grenzwertüberwachungsmodul 3Operating instructionsTwo-channel threshold monitoring m

Página 2

10• Kalibrierung und KonfigurationAllgemeinSollwert und Hysterese der einzelnen Alarmkanäle werden über die Potentiometer SET (Sollwert) und DB (Totban

Página 3

111. Schließen Sie das Gerät wie in der Tabelle oben angegeben an.2. Stellen Sie die Eingangsquelle auf den Schaltpunkt.3. Drehen Sie den Regler SET

Página 4 - Betrieb

12Interne Einstellungen (Alarmtyp und Spulenerregung)Gehen Sie wie folgt vor, um den Alarmtyp oder die Spulenerregung zu ändern:1. Nehmen Sie die lin

Página 5

13• ModifizierungLinke Seitenwand entfernen1. Lösen Sie die sechs mit A-F markierten Schneidklemmschrauben (zuvor Spannungsversorgung abschalten).2.

Página 6 - Anschlüsse

14(Entsprechend der Schrauben G & H an der linken Seite). Merken Sie sich die Lage des Isoliermaterials.Der Zusammenbau erfolgt in umgekehrter Rei

Página 7

15DPA-Hauptplatine und Darstellung der Steckbrücken für Relaisspulenerregung und Alarmfunktionen.Brücken für die Auswahl der Relaisspulenerregung:Kana

Página 8

16en DPA/TCXContentsOperation 17Installation 19Calibration and Setup 21Modifications 23

Página 9 - Thermoelementleitung

17en DPA/TCX• OperationGeneralThe DPA/TCX allows you to set two independent trip points against the temperature measured by a thermocouple. The units

Página 10

18IndicationThe front panel status LEDs indicate an alarm condition regardless of the coil energisation setting.IsolationInput, Power Supply, Alarm Ch

Página 11

19• InstallationCaution: In order to meet product safety requirements, these units must only be installed, by qualified staff, in accordance with the

Página 13 - • Modifizierung

20Protective Earth connectionEarth connections attach to a stud on the underside of the case. You must attach this connection before applying power to

Página 14

21• Calibration and SetupGeneralThe SET (setpoint) and DB (deadband) adjustments control the setpoint and hysteresis for each alarm channel. Internal

Página 15

22Deadband (DB Control) adjustmentThe deadband control adjusts the point at which a tripped alarm resets. This point will be above the setpoint for a

Página 16

23• ModificationsRemoving the left hand side plate1. Remove the six self tapping screws marked A-F (disconnect power first).2. Remove the two counter

Página 17 - Operation

24DPA main board showing the locations of the high/low operation, andrelay coil ene rgisation, selection jumpers.Relay energisation selection jumpers:

Página 21 - • Calibration and Setup

Weidmüller Interface GmbH & Co. KGPostfach 303032720 DetmoldKlingenbergstraße 1632758 DetmoldTel. +49 5231 14-0Fax +49 5231 14-20 83info@weidmuell

Página 22

3de DPA/TCXInhaltsverzeichnisBetrieb 4Installation 7Kalibrierung und Konfiguration 10Modifizierung 13

Página 23 - • Modifications

4de DPA/TCX• BetriebAllgemeinDas DPA/TCX bietet die Möglichkeit, zwei unabhängige Schaltpunkte für die von einem Thermoelement gemessene Temperatur fe

Página 24

5sowie die Spulenerregung (normalerweise erregt/nicht erregt) wird mittels interner Steckbrücken festgelegt.LED-AnzeigeDie Status-LEDs an der Frontpla

Página 25

6AnschlüsseKlemme Signal1 Nicht belegt2 Thermoelementsignal +Thermoelementeingangssignale3 Thermoelementsignal −4Nicht belegt56789 Neutral (−)Stromver

Página 26

7• InstallationAchtung: Die Installation dieser Geräte darf nur von speziell ausgebildetem Fachpersonal unter Beachtung der in dieser Dokumentation en

Página 27

8Anschluss der SchutzerdeDie Verbindung zur Schutzerde wird über einen Gewindebolzen an der Gehäuseunterseite vorgenommen. Stellen Sie sicher, dass da

Página 28

9ThermoelementleitungZur effektiven Durchführung der Kaltstellenkompensation muss eine geeignete Thermoelementleitung verwendet werden. Das DPA/TCX is

Comentários a estes Manuais

Sem comentários